Annual Service Plans for Propane Heating Equipment
17 Point Clean and Service Procedures
- Vacuum heat exchanger and firebox
- Remove and inspect glass for cracks; inspect gasket
- Clean glass
- Remove and vacuum logs, inspect for cracks and or broken logs
- Clean and inspect burner, check shutter adjustment for proper setting
- Clean and inspect burner orifice
- Clean and inspect thermocouple and thermopile
- Test ignition and safety controls
- Check operation of convection blower, if applicable
- Remove and replace batteries in remote and receiver, if applicable, (batteries extra unless customer supplied)
- Check wall switch for proper operation, if applicable
- Clean and inspect pilot orifice for proper flame pattern
- Check vents termination for blockage
- Check manifold pressure at valve; adjust, if needed according to manufacturer's specifications
- Check and inspect all wiring and connections
- Supply and install any decorative rock wool for maximum visual appearance